Measurement of Percentage Depth Dose using Fabricated Water Phantom Tank for 6 MV Photon Beam

A. M. Alssnusi, Y. A. Abdulla, N. A. Hussein, F. H. A. El-Tashani

Abstract


Radiotherapy phantoms are utilized to estimate radiation dose delivered to patients, and to improve the accuracy and measurement of radiation dosimetry. The aim of this research is to measure the percentage depth dose (PDD) using a locally designed and fabricated water phantom tank as a cost-effective alternative to the commercially available water phantom used for calibrating therapeutic radiation doses from a linear accelerator. Acrylic material was used to construct the 30 × 40 × 30 cm3 water tank, and tests were conducted on the fabricated phantom using the Elekta linear accelerator at the National Cancer Center Benghazi (NCCB). An IBA FC65-P ionization chamber was used to measure the dose at depths ranging from 0 to 16 cm in 1 cm intervals for 6 MV photon energy at 10 x 10 cm2 field size, and 100 cm source surface distance (SSD). The results indicated that the dose values obtained from the locally fabricated water phantom closely matched those from the commercially installed water phantom and were consistent with values reported in the literature.

Keywords


Local phantom; Percentage Depth Dose (PDD); Linac; Photon Beam

Full Text:

PDF

References


C. M. Washington and D. T. Leave, Principles and Practice of Radiation Therapy, 4th ed., Elsevier, St.Louis (2017).

M. Joiner and A. van der Kogel, Basic Clinical Radiobiology, 5th ed., CRC Press, Boca Raton (2018).

M. Maqbool, An Introduction to Medical Physics, Springer, Birmingham (2017).

F. M. Khan and J. P. Gibbons. The Physics of Radiation Therapy, 6th ed., Lippincott William Wilkins, Philadelphia (2019).

L. A. DeWerd and M. Kissick. The Phantoms of Medical and Health Physics, Springer, New York (2014).

M. Michelangelo, Particle Accelerators and the Progress of Particle Physics, in: Challenges and Goals for Accelerators in the XXI Century, World Scientific Publishing Co. Pte. Ltd, Singapore (2016).

N. Tsoulfanidis and S. Landsberger, Measurement and Detection of Radiation, 5th ed., CRC Press, Boca Raton (2021).

R. N. Srutil, M. M. Islam, M. M. Rana et al. Nucl. Sci. Appl. 24 (2015) 29.

M. A. AL-Naqqash, S. I. Essa, and R. H. Hassan, Iraqi J. Phys. 16 (2018) 1.

S. A. Buzdar, M. A. Rao, and A. Nazir, J. Ayub Med. Coll. Abbottabad 21 (2009) 41.

M. R. I. Chowdhury, M. F. Rabby, R. Ahmed et al., Int. J. Radiol. Radiat. Ther. 11 (2024) 100.

B. Xhafa, T. Mulaj, G. Hodolli, et al., Int. J. Med. Physics Clin. Eng. Radiat. Oncol. 3 (2014) 67.

X-J. Li , Y-C. Ye, Y.S. Zhang et al., PLOS ONE 6 (2022) 1.




DOI: https://doi.org/10.55981/aij.2025.1524



Copyright (c) 2025 Atom Indonesia

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.