Indexing metadata

Dose Response of Hp(0.07) on TLD-700 and TLD-900 Based Ring Dosimeters to the Sr-90 Exposure


 
Dublin Core PKP Metadata Items Metadata for this Document
 
1. Title Title of document Dose Response of Hp(0.07) on TLD-700 and TLD-900 Based Ring Dosimeters to the Sr-90 Exposure
 
2. Creator Author's name, affiliation, country E. B. Jumpeno; Research Organization of Nuclear Energy BRIN; Indonesia
 
2. Creator Author's name, affiliation, country R. Anggraeni; National Research and Innovation Agency BRIN; Indonesia
 
2. Creator Author's name, affiliation, country M. Muharani Putri; National Research and Innovation Agency BRIN; Indonesia
 
2. Creator Author's name, affiliation, country S. N. Barokah; National Research and Innovation Agency BRIN; Indonesia
 
2. Creator Author's name, affiliation, country F. N. Adisti; NuklindoLab; Indonesia
 
3. Subject Discipline(s)
 
3. Subject Keyword(s) Hp(0.07); TLD-700; TLD-900; Ring dosimeter; Sr-90
 
4. Description Abstract The preparation of radiopharmaceuticals may necessitate close contact with the radioactive source. In this case, high-energy beta-emitting nuclides can cause a high exposure. There are two methods of measuring the dose in the extremities, including using a bracelet and a ring dosimeter. In this study, the response of Hp(0.07) dose in TLD-700 and TLD-900-based ring dosimeters to Sr-90 beta radiation will be compared for parameters of distance, time, and angle of irradiation. The dosimeters were irradiated using Sr-90 at a distance of 5, 7, and 10 cm from the source surface and all of them were subsequently read with TLD Reader. The same type of dosimeters were exposed to Sr-90 for 1 day, 2 days, and 3 days at a distance of 7 cm and read. At a distance of 7 cm, the other dosimeters were irradiated at angles of 30°, 60°, -30°, and -60°, and then read. The study shows that the relationship between the distance of irradiation to Hp(0.07) dose is polynomial with a correlation factor of 1, both for TLD-700 and TLD-900-based ring dosimeters. The dose response at the variation of irradiation time showed linear behavior with correlation coefficients of 0.9942 and 0.9999 for TLD-700 and TLD-900, respectively. The decrease in Hp(0.07) response in TLD-700 reached 14-31 % for the irradiation angle of ±30o and 23-27 % in TLD-900 for the same angle. Meanwhile, the decrease in Hp(0.07) response at the angle of irradiation ±60o reached 48 % for TLD-700 and 66-67 % for TLD-900.
 
5. Publisher Organizing agency, location National Research and Innovation Agency
 
6. Contributor Sponsor(s) National Research and Inovation Agency and the General Manager Dosimetry Laboratory of NuklindoLab
 
7. Date (YYYY-MM-DD) 2024-11-22
 
8. Type Status & genre Peer-reviewed Article
 
8. Type Type
 
9. Format File format PDF
 
10. Identifier Uniform Resource Identifier https://atomindonesia.brin.go.id/index.php/aij/article/view/1425
 
10. Identifier Digital Object Identifier (DOI) https://doi.org/10.55981/aij.2024.1425
 
11. Source Title; vol., no. (year) Atom Indonesia; Vol 50, No 3 (2024): DECEMBER 2024
 
12. Language English=en en
 
14. Coverage Geo-spatial location, chronological period, research sample (gender, age, etc.)
 
15. Rights Copyright and permissions Copyright (c) 2024 Atom Indonesia
Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.