Dose Response of Hp(0.07) on TLD-700 and TLD-900 Based Ring Dosimeters to the Sr-90 Exposure
| Dublin Core | PKP Metadata Items | Metadata for this Document | |
| 1. | Title | Title of document | Dose Response of Hp(0.07) on TLD-700 and TLD-900 Based Ring Dosimeters to the Sr-90 Exposure |
| 2. | Creator | Author's name, affiliation, country | E. B. Jumpeno; Research Organization of Nuclear Energy BRIN; Indonesia |
| 2. | Creator | Author's name, affiliation, country | R. Anggraeni; National Research and Innovation Agency BRIN; Indonesia |
| 2. | Creator | Author's name, affiliation, country | M. Muharani Putri; National Research and Innovation Agency BRIN; Indonesia |
| 2. | Creator | Author's name, affiliation, country | S. N. Barokah; National Research and Innovation Agency BRIN; Indonesia |
| 2. | Creator | Author's name, affiliation, country | F. N. Adisti; NuklindoLab; Indonesia |
| 3. | Subject | Discipline(s) | |
| 3. | Subject | Keyword(s) | Hp(0.07); TLD-700; TLD-900; Ring dosimeter; Sr-90 |
| 4. | Description | Abstract | The preparation of radiopharmaceuticals may necessitate close contact with the radioactive source. In this case, high-energy beta-emitting nuclides can cause a high exposure. There are two methods of measuring the dose in the extremities, including using a bracelet and a ring dosimeter. In this study, the response of Hp(0.07) dose in TLD-700 and TLD-900-based ring dosimeters to Sr-90 beta radiation will be compared for parameters of distance, time, and angle of irradiation. The dosimeters were irradiated using Sr-90 at a distance of 5, 7, and 10 cm from the source surface and all of them were subsequently read with TLD Reader. The same type of dosimeters were exposed to Sr-90 for 1 day, 2 days, and 3 days at a distance of 7 cm and read. At a distance of 7 cm, the other dosimeters were irradiated at angles of 30°, 60°, -30°, and -60°, and then read. The study shows that the relationship between the distance of irradiation to Hp(0.07) dose is polynomial with a correlation factor of 1, both for TLD-700 and TLD-900-based ring dosimeters. The dose response at the variation of irradiation time showed linear behavior with correlation coefficients of 0.9942 and 0.9999 for TLD-700 and TLD-900, respectively. The decrease in Hp(0.07) response in TLD-700 reached 14-31 % for the irradiation angle of ±30o and 23-27 % in TLD-900 for the same angle. Meanwhile, the decrease in Hp(0.07) response at the angle of irradiation ±60o reached 48 % for TLD-700 and 66-67 % for TLD-900. |
| 5. | Publisher | Organizing agency, location | National Research and Innovation Agency |
| 6. | Contributor | Sponsor(s) | National Research and Inovation Agency and the General Manager Dosimetry Laboratory of NuklindoLab |
| 7. | Date | (YYYY-MM-DD) | 2024-11-22 |
| 8. | Type | Status & genre | Peer-reviewed Article |
| 8. | Type | Type | |
| 9. | Format | File format | |
| 10. | Identifier | Uniform Resource Identifier | https://atomindonesia.brin.go.id/index.php/aij/article/view/1425 |
| 10. | Identifier | Digital Object Identifier (DOI) | https://doi.org/10.55981/aij.2024.1425 |
| 11. | Source | Title; vol., no. (year) | Atom Indonesia; Vol 50, No 3 (2024): DECEMBER 2024 |
| 12. | Language | English=en | en |
| 14. | Coverage | Geo-spatial location, chronological period, research sample (gender, age, etc.) | |
| 15. | Rights | Copyright and permissions |
Copyright (c) 2024 Atom Indonesia![]() This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. |
